Shanghai Eagtop Electronic Technology Co., Ltd.

Water Cooling Reactor Data Sheet

Water Cooling Reactor Data Sheet
Product Detailed

Water Cooling Reactor Data Sheet
1.Cooling Method: Water Cooling Water Pressure: 4.0 bar Water
Flux: 16L/MIN
2.Temperatur

 Water Cooling Reactor Data Sheet

 

1.Cooling Method Water Cooling Water Pressure: 4.0 bar Water
   Flux 16L/MIN
2.Temperature Rise  < 80K
3.Dielectric Strength  AC3500V/50Hz/10mA,1min
4.Insulation Resistance  >10MΩ(DC1000V)
5.Noise Class < 65dB (to be measured at the point 1meter away
   from the reactor horizontally)
6.Protection Class  IP00
7.Temperature Class  Class H
8.Storage Temperature  -40°C~70°C
9.Working Temperature  -30°C~55°C,derating above 50°C
10.Application altitude: Rated Current below 1000 Meters, derating
   1% per 100 meters above 1000metersr
11.Application standard & Mark: EN61558-2-20(VDE0570-2-20);
   EN61800-3,CE Mark, JB-T9644, GB19212.1-2003 equal to
   IEC61558-1:1998 MOD, GB6450-86
12 Inductance: 0.09mH±5%
13.Rated Current(RMS): 1330A/phase
14.Ripple Current: < 40A (peak value), Frequency: 3kHz
15.Fundamental Frequency: 50Hz
16.Three phases, Max inductance difference between phases < 2%
17.Switching frequency of Inverse Bridge: 3kHz
18.Voltage waveform between phases: PWM pulse voltage, peak
    1500V
19.Max. dv/dt: 3000v/μS
20.Overload capacity: 105%(Continuous), 110%(30 min),150%
   (10s)
   a.No saturation during overload, while inductance vibrate less than 5%;
   b.Winding coils & Core temperature rise <100K;



Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.